PRi COAT LASTICK
Eco-friendly, two-component, elastomeric acrylic modified, cementitiousmembrane for flexible waterproofing with high levels of adhesion and durabilityof surfaces before fixing with adhesives, ideal for use in GreenBuilding. LowCO2 emissions, can itself be recycled as an inert material at the end of its life.
PRi coat lastick creates a water-resistant layer on balconies, terraces andshower cabinets before fixing tiles, even over existing coverings, doing awaywith the need for costly demolition work.
PRi COAT LASTICK
Preparation
PRi coat lastick is prepared by mixing component A with component B (present ratio of 2 : 1 in the packaging). The two components should be mixed with a suitable low-rev electrical mixer for approximately 2 minutes until a mixture with a homogenous consistency is obtained. Pour the latex into a clean recipient and gradually add the powder during the mixing operation. Leave the mixture to rest for approximately 2 minutes to allow the co-polymer to become completely dispersed and
mix again for approximately 20 seconds before use.
Application
PRi coat lastick should be applied to a previously prepared surface with a synthetic brush, plain trowel or roller. When waterproofing, apply the first coat and when the product has hardened apply the second coat in a direction transversal to the previous coat creating a minimum total thickness of 1 mm. PRi coat lastick layers must be laid with great care to ensure the surface is covered with no voids. Subsequent fixing of the covering must take place at least 24 hours after application of the last waterproofing coat, in the case of low temperatures and high humidity levels the waiting time before fixing must be extended.
Cleaning
Product residues can be removed with running water before the product has hardened.
• High adhesion to absorbent and non-absorbent substrates
• High compatibility with cement-based adhesives
• Breathable
• High workability
• Floors and walls, for internal and external use
• Suitable for overlaying
•High Crack Bridging
Waterproofing of balconies, terraces, kitchens, saunas, Turkish baths, showers before coverings in ceramic, glass mosaic and stonematerials are fixed.
Suitable for:
- concrete
- ement-based screeds/plaster
- old flooring that is dimensionally stable and anchored to a ceramic substrate
- natural stone
Do not use
Do not use on metal or wooden substrates, on bituminous coverings, to waterproof surfaces that are to be walked on and uncovered swimming pools, on lightened screeds.Do not use on metal or wooden substrates, on bituminous coverings, to waterproof surfaces that are to be walked on and uncovered swimming pools, on lightened screeds.
Preparation of substrates
- The surface must be perfectly cured and dry, solid (i.e. free of weak or easily removable parts) and free from oil, grease, paint andde-bonding agent. When working on weakened parts, when parts of the substrate are missing and also in the
case of honeycombs,the substrate must be restored with suitable repair mortars. Uneven areas must be corrected with suitable smoothing and finishingproducts. On ceramic substrates all traces of surface treatments such as wax and oil must be removed. Before application dampabsorbent surfaces without letting any stagnant water. - For external and internal angles and for water and drainage pipeline crossings use special pre-formed pieces applied using PRi coat lastick. Waterproof the structural joints with appropriate systems and arrange for continuous waterproofing..
Appearance | Part A light ready-mixed compound / Part B white latex |
---|---|
Pack | Part A 10 kg bag / Part B 5 kg can |
Mixing ratio | Part A : Part B = 2 : 1 |
Shelf life | ≈ 12 months in the original packaging in dry environment |
Warning | Liquid: protect from frost, avoid direct exposure to sunlight and sources of heat |
Pot life | ≥ 1 hr |
Temperature range for application | From + 5 °C to + 30 °C |
Maximum thickness obtainable by coat | 0.6 mm |
Waiting time between 1st and 2nd coat | ≥ 24 hrs |
Waiting time before fixing | ≥ 24 hrs |
Interval before normal use | Minimum 7 days after last coat of waterproofing membrane |
Interval before normal use | ≈ 7 days / ≈ 14 days (swimming pools) |
Specific weight of mixture | ≈ 1.7 kg/dm3UNI 7121 |
Coverage | ≈ 1.8 – 2 kg/m2 in 2 coats |
Initial adhesion | ≥ 1.5 N/mm2EN 14891–A.6.2 |
---|---|
Adhesion after contact with water | ≥ 1.2 N/mm2 EN 14891–A.6.3 |
Adhesion after heat ageing | ≥ 1.1 N/mm2 EN 14891–A.6.5 |
Adhesion after freeze-thaw cycles | ≥ 0.8 N/mm2 EN 14891–A.6.6 |
Adhesion on contact with lime water | ≥ 0.6 N/mm2 EN 14891–A.6.9 |
Adhesion on contact with chlorinated water | ≥ 0.8 N/mm2 EN 14891–A.6.7 |
Water-resistance | no penetration EN 14891–A.7 |
Crack Bridging in standard conditions | > 1 mm EN 14891–A.8.2 |
Crack Bridging at low temperatures (-5 °C) | > 1 mm EN 14891–A.8.3 |
- Product for professional use
- abide by any standards and national regulations.
- protect surfaces from sunshine, wind, rain, frost and foot traffic
- if necessary, ask for the safety data sheet