PRi ROCK BOLT GROUT

PRi ROCK BOLT GROUT

PRi ROCK BOLT GROUT

PRiBOND’S PRi Rock Bolt Grout is a non-shrink, precision grouting material for use with rock anchor bolts in mining, tunnelling and geotechnical applications. PRi Rock Bolt Grout is a Portland cementbased product that will provide low permeability, high early strength and protection from corrosion.

PACKING:

PRi Rock Bolt Grout is packaged in 40 Kg bags and yields 0.43 ft3 (0.01 m3) of fluid grout when mixed with 6.7 L of water.

 

SHELF LIFE

1 year in original, unopened package.

  • Soil nails
  • Rock bolts
  • Cable bolts
  • Pumpable
  • Highly durable
  • Non-shrink
  • High early strengths
  • Free of added chlorides

Typical Engineering Data                                                                           Compressive Strength

          The following results were developed                                            2” (50 mm) cubes (ASTM C 109)

          Under laboratory conditions.                                                           Age                                   Strength

Flowable Consistency                                                                                12 hours                          2,000 psi (14 MPa)

          6.7 L /40 kg                                                                                        24 hours                           4,000 psi (28 MPa)

Flow Rate: ASTM C 939 & CRD C 621                                                     3 days                               5,000 psi (34 MPa)

         120% Flow (flow table)                                                                     7 days                                7,000 psi (48 MPa)

                                                                                                                      28 days                               9,000 psi (62 MPa)

PRi Rock Bolt Grout should be mixed with approximately 1 gallon of water per 50 lb (22.7kg) bag. The amount of mixing water may vary due to grout temperatures. Additional variations in mixing water may be required due to pumping and placement requirements.

  • Never leave mixed grout in the pump for extended periods of time.
  • Do not add admixtures or fluidifiers.
  • Store material in dry facility.
  • Rate of strength gain is affected by temperature extremes.